FAULT FINDING CHART
REFER TO
SYMPTOM
POSSIBLE CAUSE
ACTION
SECTION
Temperature setting too
Re-adjust temperature setting
high. Temperature has
4
been set when hot water
with hot water supply at correct
temperature.
supply temperature was too
low
Inspect Check Valve (16) at
cold inlet. If the check valve
Hot water supply has
See Drg. 9309
leaks replace the pipe coupling
Mixed water
migrated into cold water
(15) and check valve
temperature too
supply
subassembly.
high
Thermostat Element has
Replace Thermostat
failed. This can be checked
6.2.1 6.2.2
Element/Slidevalve
by carrying out a hot or cold
assembly (5)
water failure test.
Remove Valve Cover (9) and
Hot valve face requires
internals and clean Hot Valve
6.3.7
cleaning
Face.
Temperature Setting too
Re-adjust temperature setting
4
low
Feel hot water supply pipe near
Hot water supply
to valve with outlet running.
3.2
temperature has fallen.
Check hot water supply system.
Mixed water
temperature too
Inspect Check Valve (16) at hot
Cold water has migrated
low
inlet. If the check valve leaks
See Drg 9309
into hot supply
replace the pipe coupling (15)
and check valve subassembly.
Cold valve face requires
Remove valve Cover (9) and
6.3.7
cleaning
clean up valve face
Partly blocked strainers
Clean strainers
-
Check all valves are full open.
Unusually high pressure
Mixed water flow
Check Pressurisation unit.
-
drop in supply pipework
rate too low.
Check mains supply
Extra Demand added to
Check pipe sizing
-
system
Thermostat Element/Slide-
Valve assembly (5) is
Valve requires de-scaling.
6.3.5
seized
Mixed water temp
does not respond
Remove HEATSTAT T2 TMV
to adjusting screw
from pipes and reverse
Hot and cold inlets reversed
-
connections. Connect inlet with
red dot to hot pipe
Thermostat Element/Slide-
Valve assembly (5) is
Valve requires De-Scaling
6.3.5
seized
Mixed water temp
Thermostat element has
changes and is not
failed. (This can be
steady
Replace Thermostat Element
6.2
checked by carrying out a
/Sidevalve assembly (5)
hot or cold water failure
test)
Water at outlet
Correct the inlet connections.
Hot and cold inlets are
runs full hot or full
Hot inlet is marked Red.
3.1
reversed
cold
Cold inlet is marked Blue.
Valve continues to
Cold valve face requires
Remove valve cover (9) and
pass cold water
6.3.7
cleaning
service cold valve face
when hot supply is
isolated
Valve continues to
Fouling at hot valve seat
Clean hot valve face
6.3.7
Issue 3 Dec 05